§ 235-13. Definitions.  


Latest version.
  • As used in this article, the following terms shall have the meanings indicated:
    AUXILIARY WATER SUPPLY
    Any water supply on or available to the premises other than the purveyor's approved public potable water supply.
    BACKFLOW
    The flow of water or other liquids, mixtures or substances, under positive or reduced pressure in the distribution pipes of a potable water supply from any source other than its intended source.
    BACKFLOW PREVENTER
    A device or means designed to prevent backflow or back-siphonage, most commonly categorized as air gap, reduced pressure principle device, double check valve assembly, pressure vacuum breaker, atmospheric vacuum breaker, hose bibb vacuum breaker, residential dual check, double check with intermediate atmospheric vent, and barometric loop.
    A. 
    AIR GAP
    A physical separation sufficient to prevent backflow between the free-flowing discharge end of the potable water system and any other system, physically defined as a distance equal to twice the diameter of the supply side pipe diameter but never less than one inch.
    B. 
    ATMOSPHERIC VACUUM BREAKER
    A device which prevents back-siphonage by creating an atmospheric vent when there is either a negative pressure or subatmospheric pressure in a water system.
    C. 
    BAROMETRIC LOOP
    A fabricated piping arrangement rising at least 35 feet at its topmost point above the highest fixture it supplies. It is utilized in water supply systems to protect against back-siphonage.
    D. 
    DOUBLE CHECK VALVE ASSEMBLY
    An assembly of two independently operating spring-loaded check valves with tightly closing shutoff valves on each side of the check valves, plus properly located test cocks for the testing of each check valve.
    E. 
    DOUBLE CHECK VALVE WITH INTERMEDIATE ATMOSPHERIC VENT
    A device having two spring-loaded check valves separated by an atmospheric vent chamber.
    F. 
    HOSE BIBB VACUUM BREAKER
    A device which is permanently attached to a hose bibb and which acts as an atmospheric vacuum breaker.
    G. 
    PRESSURE VACUUM BREAKER
    A device containing one or two independently operated spring-loaded check valves and an independently operated spring-loaded air inlet valve located on the discharge side of the check or checks. Device includes tightly closing shutoff valves on each side of the check valves and properly located test cocks for the testing of the check valve(s).
    H. 
    REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER
    An assembly consisting of two independently operating check valves with an automatically operating differential relief valve located between the two check valves, tightly closing shutoff valves on each side of the check valves plus properly located test cocks for the testing of the check valves and the relief valve.
    I. 
    RESIDENTIAL DUAL CHECK
    An assembly of two spring-loaded, independently operating check valves without tightly closing shutoff valves and test cocks. Generally employed immediately downstream of the water meter to act as a containment device.
    BACKPRESSURE
    A condition in which the owners system pressure is greater than the suppliers system pressure.
    BACK-SIPHONAGE
    The flow of water or other liquids, mixtures or substances into the distribution pipes of a potable water supply system from any source other than its intended source caused by the sudden reduction of pressure in the potable water supply system.
    CONTAINMENT
    A method of backflow prevention which requires a backflow prevention preventer at the water service entrance.
    CONTAMINANT
    A substance that will impair the quality of the water to a degree that it creates a serious health hazard to the public leading to poisoning or the spread of disease.
    CROSS-CONNECTION
    Any actual or potential connection between the public water supply and a source of contamination or pollution.
    FIXTURE ISOLATION
    A method of backflow prevention in which a backflow preventer is located to correct a cross connection at an in-plant location rather than at a water service entrance.
    OWNER
    Any person who has legal title to, or license to operate or habitat in, a property upon which a cross-connection inspection is to be made or upon which a cross-connection is present.
    POLLUTANT
    A foreign substance, that if permitted to get into the public water system, will degrade its quality so as to constitute a moderate hazard, or impair the usefulness or quality of the water to a degree which does not create an actual hazard to the public health but which does adversely and unreasonably effect such water for domestic use.
    WATER SERVICE ENTRANCE
    That point in the owner's water system beyond the sanitary control of the Town, generally considered to be the outlet end of the water meter and always before any unprotected branch.